Software Update – Exponent Lite Express
Make sure you’re using the latest features and Help we have to offer

Notes
Exponent Lite Express is for the TA.XTExpress only.
You will need to enter your original Exponent Lite Express CD number to install this software.
The latest version depends upon your operating system. See below for details.
The latest firmware is supplied with the update and can be downloaded to the TA.XTExpress using the 'Test App' software supplied with the update.
View the change history
See a summary of the changes made between versions.
As Exponent Lite Express shares the same code base as Exponent, the version numbers and change log are the same for both packages, even though some changes will not apply to Exponent Lite Express.
Version 6
For Windows 7, Windows 8.x and Windows 10. Intel 32 bit or 64 bit Multicore CPU or AMD equivalent processors are supported.
141 MB
Downloads a setup program that will update ANY previous installation of Exponent Lite Express. This will not update Texture Expert or Exceed.
This version is not compatible with Windows 95, 98, Me, NT4 or 2000.
Error in Egg Testing Haugh Unit Calculation
It has come to our attention that the Haugh Unit calculation in Exponent/Exponent Lite software (versions 6.1.15.0 and lower) has an error in the location of a bracket within the formula. This is due to how formulas are translated into computer instructions.
Incorrect: HU = 100log(h – (1.7w)0.37 + 7.6)
Correct: HU = 100log(h – 1.7w0.37 + 7.6)
We have made the appropriate correction for all future software versions (including Connect software) and can advise the following:
The grading of eggs may be affected. Changes will be most noticeable for those eggs that have a thin albumen (below 4mm) and coupled with a higher weight (e.g. 75g). For the majority of egg weights and albumen heights (that would have resulted in a high Haugh Unit) the egg grading will be unchanged.
Dough Inflation System flow rate calculation
An error was found in Exponent versions prior to 6.1.12.0 with the flow rate calculation of the Dough Inflation System Type 2 model. The adjustment for the larger piston diameter was not being made so the actual flow rate was higher than displayed in the T.A. Settings window.
For operators of the DR/DIS2 who have created their own projects or made copies of the sample projects, the Dough Inflation System will continue to operate in the same way as before i.e. the displayed value of 26.7 will continue to operate at the actual flow rate of 60.9 cm3/sec for compatibility with existing results.
The new sample projects and library sequences (supplied from version 6.1.12.0 onwards) correct this issue and run at the displayed flow rate i.e. 26.7 cm3/sec. Operators who have been directly using sample projects from previous Exponent versions, and wish to continue using the same flow rate as the previous versions, will need to change the flow rate value to 60.9 cm3/sec.
Version 5
For Windows 2000 (Service Pack 4), XP (Service Pack 2 or higher), Vista and Windows 7.
55.1 MB
Downloads a setup program that will update ANY previous installation of Exponent Lite Express. This will not update Texture Expert or Exceed.
This version is not compatible with Windows 95, 98, Me, NT4.
Version 4
For Windows 98, Me
80.8 MB
This version is not compatible with Windows 95 or NT4.
Notes
Using Exponent 32 on NT
Windows NT has extra security features that can prevent access to files and folders on a per user basis. This can prevent Exponent from saving some user configuration parameters. One of the common indications that security permissions are a problem is an error message that states the Testlog can not be accessed or locked after a test is complete. You may also find that your Macro and Project manager settings are not accepted.
To ensure this does not inconvenience users then all the files and directories located in the TE32 "Application Data" directory specified by Windows need to have read/write privileges. This is normally something like "C:\Documents and Settings\All Users\Application Data\StableMicroSystems\TE32" but you can find out for sure in the About box of Exponent (Help > About menu command)
Exponent tries to create the permissions when it creates the folder but this may fail if the active users NT permissions are not sufficient. For this reason it is recommended that Exponent is run for the first time by a user with Administrator rights on NT.
Some global settings are stored in the HKEY_LOCAL_MACHINE\Software\Stable Micro Systems\TEE32 branch of the registry. If you need to allow users to change these global settings then the security settings of this branch will also need to be configured accordingly. Normally these settings are not changed very often so provided Exponent is initially configured by an NT administrator then the standard privileges should be OK for normal use. Exponent tries to create the permissions when it creates the registry entry but this may fail if the active users NT permissions are not sufficient. For this reason it is recommended that Exponent is run for the first time by a user with Administrator rights on NT.
The following items are stored in this branch of the registry:
• Com port
• User List
• Aux channel mappings
• RS485 channel mappings
• Registration details
Using Exponent on Vista