45mm Quick Twist Probe Adapter

AD/45QT Registered Community Design

Product overview

For Texture Analyser users who are looking for ways to increase their sample testing throughput and improve the convenience of probe attachment to their Texture Analyser, we have two innovative options. Users can now choose to have a converter fitted to their probes to allow for quick removal and replacement between tests. These converters require an adapter for attachment to the Load Cell.

Either ‘magnetic’ or ‘quick-twist’ probe converters and adapters are available. These quick probe removal and replacement options support the requirement for test procedures that have efficiency and/or convenience in mind. 

Technical information

Manufacturing material Aluminium
Maximum operating temperature 200°C

Benefits and limitations

Whilst a magnetic coupling might be the preferred and simplest attachment action, it is not suited to the testing of samples that do not have a flat surface, or samples that have an adhesive force measurement exceeding 1.5kg. Therefore, the Quick Twist Probe Adapter may be more suitable for any application and all Load Cell models. 

Installation

Full installation instructions are provided within the Education Zone of the latest Exponent/Connect software version and on the technical information sheet accompanying this product.

Chemical compatibility

Stable Micro Systems probes and attachments are commonly made from four materials: anodised aluminium (AA6082 T6), stainless steel (316 T), Delrin (acetyl copolymer) and Perspex (polycarbonate).

In general use, probes and attachments made from these materials will be suitable for testing food products and inert non-food materials.

The four materials listed above are not universally resistant to all types of chemicals and as such the compatibility of the probe/attachment material with the product (to be tested) must be established to prevent damage to the probes and attachments. If the compatibility of the product with the probe is unknown to the customer then the chemical information about the product (Material Safety Data Sheet or Product Data Sheet) should be submitted to Stable Micro Systems. Stable Micro Systems will then assess the suitability of the probe/attachment material for use with the product and advise accordingly. If this advice is not sought then Stable Micro Systems will not accept liability for probes/attachments damaged by chemical attack from the product being tested.

Cleaning and maintenance

All probes and attachments may be cleaned in warm (or hand hot) water using a mild detergent. A soft brush may be used but abrasive cleaning aids should be avoided. Stable Micro Systems products should not be microwaved or cleaned in a dishwasher.

Screw threads should be lightly lubricated after drying using a light lubricant, e.g. petroleum jelly, mineral oil. This will aid the fitting and unscrewing of the item. Each component of a probe or attachment should be wrapped separately when stored, to avoid scratching or chipping. This will safeguard against any unnecessary damage to the accessory.